A Reliable Method for Diagnosing Meniscal Tears in the Knee Using 0.3 Tesla MRI
DOI:
https://doi.org/10.62019/zdkh8j22Keywords:
MRI, Arthroscopy, Knee ReplacementAbstract
Objective: The purpose of this research is to evaluate the diagnostic accuracy of arthroscopic findings versus a 0.3-tesla MRI for meniscal damage in the knee.
Methodology: Eighty individuals were sent from the orthopaedic clinic who met the inclusion criteria for the study. This 0.3 Tesla scan was done by just one MRI technician. A professor of orthopedics performed an arthroscopy to corroborate the MRI's findings. Using a proforma spreadsheet, we recorded and examined all of the information.00
Results Out of the total, 72 were males (or 90%) and 8 were females (or 10%). Mean age of the cases was 27.16 years. Contrary to arthroscopy, MRI was more sensitive (98%), specific (94%), and accurate (96%), when it came to identifying meniscal lesions of the knee joint.
Conclusion: We found that magnetic resonance imaging (MRI) is a safe, accurate, and noninvasive way to assess meniscal injuries.
Downloads
Downloads
Published
Issue
Section
License
All articles published in the Journal of Medical & Health Sciences Review (JMHSR) remain the copyright of their respective authors. JMHSR publishes its content under the Creative Commons Attribution‑NonCommercial 4.0 International License (CC BY‑NC 4.0), which allows readers to freely share, copy, adapt, and build upon the work for non‑commercial purposes, provided proper credit is given to both the authors and the journal.